EBS beta point sources for measuring instruments

Through LEA, Orano provides EBS beta point sources whose diameter, activity and radionuclide can be adapted to your requirements. Their design incorporates a vacuum-deposited gold coating on each side to optimize measurement efficiency.
    • Adapting the source dimensions to your measurement configuration
    • Selecting the radionuclide and activity suited to your requirements
    • Optimizing the source’s measurement efficiency
    • Using sources whose radiological characteristics are measured with calibrated equipment
    • Planning source replacement according to their metrological lifetime and physical integrity
    • Benefit from three standard geometries featuring a 3 mm active diameter and different overall diameters
    • Adapt the active diameter, overall diameter and activity with configurations available on request
    • Select your radionuclide from catalogue references or options available on request
    • Optimize measurement efficiency with a vacuum-deposited gold coating applied to each side of the source
    • Rely on a design combining two heat-sealed polyester sheets and a steel ring
    • Control radiological characteristics through measurements performed using a calibrated gas-flow proportional counter
    • Simplify source grouping with EBS A and EBS B sets available in several configurations
    Dimensions and activity tailored to your needs
    10 years: Recommended lifetime for physical integrity
    • Standard geometries: Type A, Type B, Type C (detailed characteristics shown in the source images)
    • Dimensions available on request: active diameter from 3 to 30 mm and overall diameter from 25 to 60 mm
    • Catalogue activities: 0.8 kBq and 3 kBq
    • Activities available on request: from 0.05 to 4 kBq
    • Catalogue radionuclides: ²²Na, ³⁶Cl, ⁶⁰Co, ⁹⁰Sr/⁹⁰Y, ¹³⁷Cs/¹³⁷Ba, ¹⁴⁷Pm, ²⁰⁴Tl, ¹³⁴Cs and ⁸⁹Sr
    • Radionuclides available on request: ³²P, ³⁵S, ⁴⁵Ca and ⁹⁹Tc
    • Construction: radionuclides deposited between two heat-sealed polyester sheets, each approximately 75 µm thick
    • Measurement optimization: vacuum-deposited gold coating applied to each side of the source
    • Support: assembly mounted in a steel ring
    • Radiological characterization: measurements performed using a calibrated gas-flow proportional counter
    • Sets: EBS A and EBS B sources available with ¹⁴⁷Pm, ¹³⁴Cs, ¹³⁷Cs, ⁹⁰Sr + ⁹⁰Y, ²⁰⁴Tl or ²²Na, with an activity of 80 Bq or 3,000 Bq
    • Set configurations: other combinations of EBS sources available on request